中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Marine, OIL,GAS & Petrochemical Cables
Norwegian Offshore cables British Standard Offshore cables European Standard Offshore cables JIS Offshore cables UKOOA Offshore cables

Oil rig cable

Single conductor unarmored power cable 600V & 2000V

Application

Single conductor 600 and 2000 volt cable is an extremely tough construction ideally suited for use in rugged marine/oil rig applications. The insulation has outstanding resistance to abrasion, cut-through, low and high temperatures, petrochemical fluids, sunlight, and moisture. The material also has excellent flame retardance, acid gas, and electrical characteristics.

Standards

  • IEEE-45, /IEEE 1580 Type P
  • UL 1309 Marine Shipboard Cable (File E83358)
  • CSA C22.2 No. 245 Marine Shipboard
  • Performance Requirements of IEC 92-3
  • Insulation ICEA Standard S-95-658 and NEC Type XHHW
  • IEC 60092-353
  • Meets requirements of 46 CFR Parts 110 and 111

Construction

  • Conductor: Annealed, Tinned copper per ASTM B33, B8 and B172
  • Insulation: Irradiated crosslinked polyolefin (Colors – as required)

600V

Number of
( conductors
AWG/ MCM mm² Stranding
(Number of
(strand/strand
diameter AWG)
Insulation
thickness
( mm
Nominal overall
diameter mm
Approx. net weight
(lbs/m
Kg/km
1 18 0.96 19/30 0.76 2.72 11 16
1 16 1.22 19/29 0.76 2.90 13 19
1 14 1.94 19/27 0.76 3.23 18 27
1 12 3.08 19/25 0.76 3.71 27 40
1 10 5.53 27/24 0.76 4.65 45 68
1 8 7.58 37/24 1.14 5.87 65 97
1 6 12.50 61/24 1.14 7.11 101 152
1 5 18.60 91/24 1.14 8.38 149 222
1 4 21.50 105/24 1.14 8.89 165 248
1 3 25.00 125/24 1.14 9.53 195 290
1 2 30.70 150/24 1.14 10.41 233 358
1 1 46.00 225/24 1.40 12.57 343 515
1 1/0 56.30 275/24 1.40 13.84 408 612
1 2/0 66.50 325/24 1.40 14.99 481 722
1 3/0 92.10 450/24 1.40 16.76 653 980
1 4/0 112.60 550/24 1.40 18.29 790 1176
1 262 133.00 650/24 1.65 19.94 931 1385
1 313 158.60 775/24 1.65 21.59 1099 1635
1 373 189.30 925/24 1.65 22.86 1300 1934
1 444 225.10 1100/24 1.65 24.89 1551 2308
1 535 271.20 1325/24 2.03 28.20 1930 2895
1 646 327.00 1600/24 2.03 30.86 2250 3348
1 777 394.00 1925/24 2.03 32.51 2670 3973
1 1111 563.00 2750/24 2.80 38.90 3780 5625

2000V

Number of conductors AWG/ MCM mm² Stranding (Number of strand/strand diameter AWG) Insulation Thickness mm Nominal overall diameter mm Approx. net weight Lbs/m Kg/km
1 18 0.97 19/30 1.14 3.47 15 23
1 16 1.22 19/29 1.14 3.66 17 25
1 14 1.94 19/27 1.14 3.99 23 35
1 12 3.08 19/25 1.14 4.47 32 48
1 10 5.53 27/24 1.14 5.41 50 75
1 8 7.58 37/24 1.40 6.40 71 106
1 6 12.50 61/24 1.40 7.75 105 157
1 5 18.60 91/24 1.40 8.99 157 234
1 4 21.50 105/24 1.40 9.50 176 264
1 3 25.00 125/24 1.40 10.13 208 312
1 2 30.70 150/24 1.40 11.02 240 358
1 1 46.00 225/24 1.65 13.18 360 540
1 1/0 56.30 275/24 1.65 14.35 435 653
1 2/0 66.50 325/24 1.65 15.50 492 738
1 3/0 92.10 450/24 1.65 17.25 685 1028
1 4/0 112.60 550/24 2.67 20.83 852 1278
1 262 133.10 650/24 2.67 21.89 981 1460
1 313 158.70 775/24 2.67 23.62 1131 1670
1 373 189.00 925/24 2.67 24.89 1354 2031
1 444 225.20 1100/24 2.67 25.92 1607 2410
1 535 271.30 1325/24 3.05 29.60 1994 2990
1 646 327.00 1600/24 3.05 32.89 2303 3455
1 777 394.00 1925/24 3.05 34.54 2734 4100
1 1111 563.00 2750/24 3.05 40.13 3743 5615